Aid 4D probe; acknowledge the probe by means of the ID code; swap the 4D drive signal by way of the electrical relay for making the 4D probe get the job done Typically. 4.two.2 Major board The main board could possibly be divided into two areas: entrance-conclusion of the most crucial board and again-end of the key board.
Utmost four situations tasking for a single transmitted beam, leading to fantastic time resolution and better frame rate.
Get a complete and prolonged watch in the anatomical structure by panoramic imaging coupled with velocity indication and ahead/backward scan capability producing scanning much easier, smoother plus more controllable.
Do not use any cables in addition to the cables provided with the unit by Mindray. 3. Use the cable supplied with this system to attach the printer. Other cables may well result in electrical shock. Webpage 15: Mechanical Safety
Click on Concur and Continue to simply accept cookies and go straight to the site or click More info to see specific descriptions of the types of cookies and pick regardless of whether to accept particular cookies even though on the site.
Any time you end the scanning along with the image capture, you'll want to electric power from the program and disconnect the system with the AC electrical power offer, then pull out AC energy cables. Web site 109: Battery Connecting Board
The chapter provides the strategy to validate primary purpose and performance of merchandise. This can be only employed for reference, not preventive execution. Purpose examining and screening of this element shall be completed by Mindray assistance engineers and the person together. Webpage 66: Standard Examination
Learn much better diagnostic information and facts by means of extended look at in the anatomical composition on all convex probes.
iZoom™ permits accurate viewing of impression from distance iWorks™ Protocol assists standardize workflow and lower Test situations
five.two.three Geometric positioning accuracy Longitudinal geometric positioning precision Test Stage: Do adjustments as just how in tests the maximum depth. History the space by 20mm Every single phase to the longitudinal targets line utilizing the measurement caliper; Pick the value with the greatest mistake (to 20mm), compute the precision using the method underneath The measurement caliper ought to be positioned for the upper fringe of the goal, NOTE:... Web page 79 Transverse geometric positioning accuracy Exam Move: Include the scan surface with the phantom with h2o or few gel, gently contact the probe With all the scan floor Modify the depth, creating the transverse targets to get exhibited in the image. Change the focus position being posited beside the transverse targets (the regular is not really clear) Alter parameters like obtain, TGC, producing each transverse targets to be clearly exhibited. Web site eighty five.5.two.four Blackout Place Check Stage: Deal with the scan surface in the phantom with drinking water or couple gel, Carefully Speak to the probe Along with the scan area Adjust the depth in a lower price, and set the focus at the closest location to the scan surface area. Reduce the worth of parameters like AP, Attain right until the qualifications noise just could be observed. Web page eighty one: Application Update And Routine maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Find out much better diagnostic details by means of prolonged look at with the anatomical structure on all linear probes
Effectiveness Test five.five.1 Test Process Resolution Detection depth Geometric Situation Accuracy Blackout area exam Report the exam visuals 5.5.2 Exam Articles The graphic applied Here's only for reference, stay with the image effect in the real Notice: situation. Prerequisites: Screen: set the contrast and brightness with the scientific software price (or maybe the default position) Procedure surroundings: dark place, simulating the medical software setting. Web page 76 In issue that the transverse resolution testing targets are horizontally exhibited, report the nominal length of two targets that could be Evidently regarded. Repeat the operation over for the transverse resolution tests targets at other depths. As demonstrated in figure down below. Axial resolution ... Site 77 When utilizing the convex probe, retain the transverse resolution testing targets to NOTE: be displayed near the midline. When employing a linear probe with steer purpose, usually do not activate the steer perform when perform the transverse resolution examination. Zoom while in the area in which the targets Positioned if required. The diameter with the target point at a particular depth is equivalent to your transverse resolution in the depth. Webpage 78 five.
Mindray respects your privateness. We use cookies for a number of applications, like Web site functionality, improving your experience of our website, setting up integration with social websites and aiding concentrate Dp50rb on our marketing.
Return to your program preset interface. The choice position modifications into Uninstalled. The uninstalling functionality is unique to inside users.